Product · Cable Trunking
Cable Trunking
Enclosed steel trunking for cable runs that need protection, segregation, and a tidy route, in switchrooms, clean rooms, life-safety risers, and the exposed service voids of modern offices. TKC perforated and TKU plain, in standard widths from 100 to 1000 millimetres and heights of 50, 100, or 150 mm. Hot-dip galvanised, pre-galvanised, or Jotun powder-coated to match the architectural palette of the room.

Cable Trunking · Tangerang Facility
Dimensions
Fabricatable ranges.
Every order is cut to specification. The ranges below describe what we fabricate as standard at the Tangerang line — extended dimensions are available on engineering request.
| Specification | Range |
|---|---|
| Widths | 100 – 1000 mm |
| Depths | 50 – 150 mm |
| Material thickness | 1.0 – 2.5 mm |
| Standard lengths | 2400 mm · 3000 mm |
| Cover types | Plain · perforated · hinged |
| Finishes | Hot-dip galvanised · Powder-coated (Jotun) |
Applications
Where this line lives.
-
Switchroom and MEP-room segregation of power, control, and data circuits, each trunking sized to its cable family.
-
Life-safety risers and segregated power runs in multi-storey buildings, for cables that must not share tray with other services.
-
Exposed architectural runs in offices and hotels, powder-coated to the ceiling or wall colour.
Enclosed, segregated, specifiable
A Metosu cable trunking is a rectangular steel channel with a removable cover, bolted or clipped to structure. It gives cables that must not share tray a fully enclosed route, protects them from mechanical damage, and keeps the services plan in a sealed run rather than an open one. For the segregation rules between power and data, see our guide.
Cover types
Plain covers for runs that stay fully enclosed. Perforated covers for heat dissipation and for runs that need a visual check. Hinged covers for the zones opened often, such as behind MDF panels or above demountable ceilings.
Finish for the visible work
Where the trunking is seen, such as the exposed service voids of modern Jakarta offices or ceiling feature strips in hotel lobbies, we finish on the Jotun line: 60–80 µm of dry powder coating, cured at 180°C, to any RAL. Hot-dip galvanised and pre-galvanised are available for outdoor runs and dry indoor runs.
Standard cable trunking sizes
These are the standard sizes in our catalogue, in 3 metre lengths. TKC and TKU share the same geometry. The only difference is the perforation: TKC is perforated, TKU is plain.
| Width (mm) | Height (mm) | Length (mm) | TKC (perforated) | TKU (plain) |
|---|---|---|---|---|
| 100 | 50 | 3,000 | TKC 100/50 | TKU 100/50 |
| 150 | 50 | 3,000 | TKC 150/50 | TKU 150/50 |
| 200 | 50 | 3,000 | TKC 200/50 | TKU 200/50 |
| 450 | 100 | 3,000 | TKC 450/100 | TKU 450/100 |
| 500 | 100 | 3,000 | TKC 500/100 | TKU 500/100 |
| 600 | 150 | 3,000 | TKC 600/150 | TKU 600/150 |
| 700 | 150 | 3,000 | TKC 700/150 | TKU 700/150 |
| 800 | 150 | 3,000 | TKC 800/150 | TKU 800/150 |
| 900 | 150 | 3,000 | TKC 900/150 | TKU 900/150 |
| 1000 | 150 | 3,000 | TKC 1000/150 | TKU 1000/150 |
Need a size outside the table? Custom widths, heights, and lengths are made to your project drawing.
Fittings and transitions
Inside and outside risers for vertical-to-horizontal transitions, flat-wise elbows and crosses for horizontal turns, equal tees, and reducers. Each fitting has its part code and drawing in the catalogue.
Get a cable trunking price
We don’t publish a price list, because cable trunking pricing depends on size, finish, and quantity. Send your schedule or drawing on WhatsApp and our technical team will come back with a recommendation and a quotation.
Get a quote on WhatsAppFAQ
Questions buyers ask us.
- What are the standard cable trunking sizes?
- Ten standard sizes, from 100 x 50 mm up to 1000 x 150 mm, in 3 metre lengths. The full table is on this page and in the catalogue. Sizes outside the table are made to your project drawing.
- What is the difference between TKC and TKU?
- The geometry is identical. TKC is perforated, TKU is plain. Part codes follow the same size, for example TKC 200/50 and TKU 200/50.
- When should I use trunking instead of cable tray?
- Use trunking where the cables need full enclosure, such as low-voltage, control, data, or segregated power cabling, including clean-room and life-safety wiring. Use cable tray for medium-density distribution where some dust protection is wanted but full enclosure is not required.
- Which trunking fittings are available?
- Inside and outside risers, flat-wise elbows, flat-wise crosses, equal tees, and reducers. Each fitting has its part code and technical drawing in the catalogue.
- What finishes are available for trunking?
- Hot-dip galvanised, pre-galvanised, or Jotun powder coating, and every standard size is available in all three. Jotun suits the exposed runs in offices and hotels, in any RAL colour.
Request a Quote
Tell us about your project.
Next
Specify the right run for your project.