Skip to main content
Metosu

Product · Cable Trunking

Cable Trunking

Enclosed steel trunking for cable runs that need protection, segregation, and a tidy route, in switchrooms, clean rooms, life-safety risers, and the exposed service voids of modern offices. TKC perforated and TKU plain, in standard widths from 100 to 1000 millimetres and heights of 50, 100, or 150 mm. Hot-dip galvanised, pre-galvanised, or Jotun powder-coated to match the architectural palette of the room.

Cable Trunking — Metosu engineered render

Cable Trunking · Tangerang Facility

Dimensions

Fabricatable ranges.

Every order is cut to specification. The ranges below describe what we fabricate as standard at the Tangerang line — extended dimensions are available on engineering request.

Cable Trunking dimensions
Specification Range
Widths100 – 1000 mm
Depths50 – 150 mm
Material thickness1.0 – 2.5 mm
Standard lengths2400 mm · 3000 mm
Cover typesPlain · perforated · hinged
FinishesHot-dip galvanised · Powder-coated (Jotun)

Applications

Where this line lives.

  • Switchroom and MEP-room segregation of power, control, and data circuits, each trunking sized to its cable family.

  • Life-safety risers and segregated power runs in multi-storey buildings, for cables that must not share tray with other services.

  • Exposed architectural runs in offices and hotels, powder-coated to the ceiling or wall colour.

Enclosed, segregated, specifiable

A Metosu cable trunking is a rectangular steel channel with a removable cover, bolted or clipped to structure. It gives cables that must not share tray a fully enclosed route, protects them from mechanical damage, and keeps the services plan in a sealed run rather than an open one. For the segregation rules between power and data, see our guide.

Cover types

Plain covers for runs that stay fully enclosed. Perforated covers for heat dissipation and for runs that need a visual check. Hinged covers for the zones opened often, such as behind MDF panels or above demountable ceilings.

Finish for the visible work

Where the trunking is seen, such as the exposed service voids of modern Jakarta offices or ceiling feature strips in hotel lobbies, we finish on the Jotun line: 60–80 µm of dry powder coating, cured at 180°C, to any RAL. Hot-dip galvanised and pre-galvanised are available for outdoor runs and dry indoor runs.

Standard cable trunking sizes

These are the standard sizes in our catalogue, in 3 metre lengths. TKC and TKU share the same geometry. The only difference is the perforation: TKC is perforated, TKU is plain.

Standard cable trunking sizes
Width (mm) Height (mm) Length (mm) TKC (perforated) TKU (plain)
100503,000TKC 100/50TKU 100/50
150503,000TKC 150/50TKU 150/50
200503,000TKC 200/50TKU 200/50
4501003,000TKC 450/100TKU 450/100
5001003,000TKC 500/100TKU 500/100
6001503,000TKC 600/150TKU 600/150
7001503,000TKC 700/150TKU 700/150
8001503,000TKC 800/150TKU 800/150
9001503,000TKC 900/150TKU 900/150
10001503,000TKC 1000/150TKU 1000/150

Need a size outside the table? Custom widths, heights, and lengths are made to your project drawing.

Fittings and transitions

Inside and outside risers for vertical-to-horizontal transitions, flat-wise elbows and crosses for horizontal turns, equal tees, and reducers. Each fitting has its part code and drawing in the catalogue.

Get a cable trunking price

We don’t publish a price list, because cable trunking pricing depends on size, finish, and quantity. Send your schedule or drawing on WhatsApp and our technical team will come back with a recommendation and a quotation.

Get a quote on WhatsApp

FAQ

Questions buyers ask us.

What are the standard cable trunking sizes?
Ten standard sizes, from 100 x 50 mm up to 1000 x 150 mm, in 3 metre lengths. The full table is on this page and in the catalogue. Sizes outside the table are made to your project drawing.
What is the difference between TKC and TKU?
The geometry is identical. TKC is perforated, TKU is plain. Part codes follow the same size, for example TKC 200/50 and TKU 200/50.
When should I use trunking instead of cable tray?
Use trunking where the cables need full enclosure, such as low-voltage, control, data, or segregated power cabling, including clean-room and life-safety wiring. Use cable tray for medium-density distribution where some dust protection is wanted but full enclosure is not required.
Which trunking fittings are available?
Inside and outside risers, flat-wise elbows, flat-wise crosses, equal tees, and reducers. Each fitting has its part code and technical drawing in the catalogue.
What finishes are available for trunking?
Hot-dip galvanised, pre-galvanised, or Jotun powder coating, and every standard size is available in all three. Jotun suits the exposed runs in offices and hotels, in any RAL colour.

Request a Quote

Tell us about your project.

Your details are used only to reply about your project. We do not send marketing emails.

Next

Specify the right run for your project.

Engineer a specification →